PRODUCT SPECIFICATIONS

  • Four specifications of 12″ 24″ 36 “48” 60″ 72″on models. 28,000; 56,000; 84,000; 112,000; 140,000; 168,000BTU/h
  • Gas control knob every 12”
  • Thermostat range 200°-450°F(93°C-232°C)
  • Cool-to-the-touch front S/S edge
  • All stainless steel cabinet, Standing pilot ignition system
  • Back and side splash guards fully welded to griddle plate
  • Adjustable stainless steel non-skid feet
  • Easy to remove 4 1/2”quart grease drawer with weep hole
  • Shipped standard Natural gas, LP conversion it included.

MODEL LIST

Model Gas Type Burners Total BTU Overall Dimensions Net Weight Package Size Shipping Weight
CP-G12-TP Natural Gas / Liquid Propane 1 28,000 12″ x 28.7″ x 15.4″ (30.4 x 72.8 x 39.4 cm) 117 lbs (53 kg) 15.75″ x 35.5″ x 19.25″ (40 x 85 x 49 cm) 143 lbs (65 kg)
CP-G24-TP Natural Gas / Liquid Propane 2 56,000 24″ x 28.7″ x 15.4″ (60.9 x 72.8 x 39.4 cm) 156 lbs (71 kg) 27.5″ x 35.5″ x 19.25″ (70 x 85 x 49 cm) 240 lbs (109 kg)
CP-G36-TP Natural Gas / Liquid Propane 3 84,000 36″ x 28.7″ x 15.4″ (91.4 x 72.8 x 39.4 cm) 220 lbs (100 kg) 39.5″ x 35.5″ x 19.25″ (100 x 85 x 49 cm) 338 lbs (154 kg)
CP-G48-TP Natural Gas / Liquid Propane 4 112,000 48″ x 28.7″ x 15.4″ (122 x 72.8 x 39.4 cm) 348 lbs (158 kg) 51.25″ x 35.5″ x 19.25″ (130 x 85 x 49 cm) 424 lbs (193 kg)
CP-G60-TP Natural Gas / Liquid Propane 5 140,000 60″ x 28.7″ x 15.4″ (153 x 72.8 x 39.4 cm) 484 lbs (220 kg) 63″ x 35.5″ x 19.25″ (160 x 85 x 49 cm) 567 lbs (258 kg)
CP-G72-TP Natural Gas / Liquid Propane 6 168,000 72″ x 28.7″ x 15.4″ (182.9 x 72.8 x 39.4 cm) 651 lbs (296 kg) 75″ x 35.5″ x 19.25″ (190 x 85 x 49 cm) 759 lbs (345 kg)

PLAN VIEW

  • This appliance is manufactured for commercial installation only, not intended for home use
  • 3/4″ NPT rear gas connections. Supply gas pressure not to exceed 14” W.C.(1/2 PSI)

Natural gas operating pressure – 5.0” W.C, Recommended supply pressure 7-9” W.C

Propane gas operating pressure – 10.0” W.C, Recommended supply pressure 11-12” W.C

  • A gas pressure regulator supplied with unit must be installed
  • An adequate ventilation system is required for Commercial Cooking Equipment
  • Require a 6” clearance at both side and rear adjacent to combustible construction